Features

Magnetically operated switches are designed for resistance to water and oily environments. Connection is made through an underwater pluggable connector. Operation is by remote magnet.

crossrule_orange

Applications

• Water-current meter: activating magnet mounts to propeller blade.
• Valve-position indicator: activating magnet, mounted on valve, triggers switch.
• Mechanical-movement monitoring; activating magnet mounts on moving machinery.

 

Electro Series 610 Waterproof, Magnetically Operated Switches

Switch

Contact arrangement: SPST-NO
Contact material: Rhodium Standard

Enclosure

Internal construction: Switch potted in Micarta base block, screw attached to brass mounting stud.
Stud mounting: 3/8"-24, 1/2" long with 3/8" washer and 3/8"-24 hex nut.
Enclosure: Specially formulated neoprene rubber, nonwetting surface.
Insulation resistance: 100 megohms contact-to-contact in water.

Switch Electrical Specifications

Insulation resistance: 100 megohms.
Life expectance: 10 X 106, full rating.
Contact rating: 10 w dc, 0.5 amp maximum.
Actuating time: 1 millisecond.
Contact bounce: 1 millisecond.
Actuating rate: Depending on drive, can follow up to 400 cycles per second.

More information is available. Click [HERE] to download our product sheet.
 

Contact

Cooper Interconnect
4758 Washington St.
LaGrange, NC 28551

P: 252-566-3014
F: 252-566-9337
info@cooperinterconnect.com

crossrule_orange

Electro Series 610 Waterproof,
Magnetically Operated Switches

 

Cooper Interconnect is a trademark of Cooper Crouse-Hinds, LLC. © 2007-2008 Cooper Crouse-Hinds, LLC.

Designed and maintained by AdSpeak Marketing Communications, 215.343.6565, www.adspeak.com