• Low source shock

• Electrically redundant

• Ability to actuate without preload

• Instantaneous release
   (simultaneous release possible)

• Resettable (by replacing initiators)

• Utilize pyro circuits

• Space rated materials

crossrule_orange

Specifications

• Attachment: M4 X .78" long
   thread fitting

• Ultimate load: 540 lb.

• Rated Release Load: 276 lb.

• Actuation Circuit: 5 amps @
   5 VDC per circuit

• Actuation Time: 25 milliseconds max.

• Temperature Range: -40 to +120 °C

• Weight: 250 grams
 